FEATURES, SPECIFICATIONS AND BENEFITS
|
MODEL 1042LH

|
MODEL 1137

|
|
APPLICATION
|
Flow-through humidifier that's ideal for most homes. Installs on vertical warm air supply or cold air return plenum.
|
Flow-through humidifier that's ideal for most homes. No by-pass required. Installs on vertical warm air supply plenum.
|
|
UNIT SIZE
|
15" wide x 11-1/2" high x 9" deep
|
16" wide x 14" high x 10" deep
|
|
PLENUM OPENING
|
10-1/4" wide x 9-1/2" high
|
15" wide x 9-1/2" high
|
|
BYPASS DUCT
|
6" diameter (collar supplied)
|
N/A
|
|
EVAPORATIVE OUTPUT CAPACITY @ .20" PRESSURE DIFFERENTIAL (except 747 rated at 800 FPM duct velocity) ABOVE AT STANDARD INDUSTRY RATING CONDITIONS
|
| Temp ºF |
GPD |
Temp ºF |
GPD |
80º 100º 120º
|
8.0 12.2 16.4
|
140º 160º
|
19.2 23.2
|
|
| Temp ºF |
GPD |
Temp ºF |
GPD |
80º 100º 120º
|
10.4 14.4 17.7
|
140º 160º
|
21.3 25.3
|
|
|
EVAPORATIVE PRINCIPLE GENERALAire humidifers are 100% evaporative, adding moisture in the form of water vapor only. They are clean operating. The nuisance of airborne water droplets or mineral dust is avoided.
|
Forced warm air heating systems create a pressure differential that diverts some heated air to the humidifier through a bypass duct. There, the warm air absorbs moisture from a water-soaked evaporator pad and then rejoins the primary warm air stream for distribution throughout the living area. A solenoid valve and patented distribution tray meter and disperse water uniformly across the evaporator pad. Unevaporated water drains from the unit.
|
A motor-driven fan directs a portion of the heated air through the water-soaked evaporator pad. The warm air absorbs moisture and returns through internal baffles to the primary warm air stream for distribution throughout the living area. A solenoid valve and patented distribution tray meter and disperse water uniformly across the evaporator pad. Unevaporated water drains from the unit.
|
|
EVAPORATIVE MEDIA
|
990-13 Evaporator Pad. Designed for high output with minimal hard water scale accumulation. UL listed.
|
990-13 Evaporator Pad. Designed for high output with minimal hard water scale accumulation. UL listed.
|
|
WATER SUPPLY
|
Dependable stainless steel solenoid valve with monel wire mesh filter that protects the precision machined Teflon flow-control orifice. Saddle valve supplied. Use 1/4" copper tubing.
|
Dependable stainless steel solenoid valve with monel wire mesh filter that protects the precision machined Teflon flow-control orifice. Saddle valve supplied. Use 1/4" copper tubing.
|
|
DRAIN CONNECTION
|
High capacity 5/8" drain and hose prevents clogging. Includes 15' vinyl hose except recircating models.
|
High capacity 5/8" drain and hose prevents clogging. Includes 15' vinyl hose except recircating models.
|
|
RANGE OF MODELS
|
1042 - line voltage
1042-L - low voltage
1042-LH - low voltage w/H-86 Humidistat
1042-R - recirculating, no drain required, with time-tested Model 975 Recirculating Pump
|
1137 - line voltage
1137-R - recirculating, no household drain required, with time-tested Model 975 Recirculating Pump
|
|
ELECTRICAL
|
1042 - 115 V. 60 Hz.
1042-L - 24 V. 60 Hz.
1042-LH - 24 V. 60 Hz.
1042-R - 115 V. 60 Hz.
(L/LH models - transformer supplied)
|
1137 - 115 V., 1.0 Amp, 60 Hz.
1137-R - 115 V., 1.6 Amp, 60 Hz.
(Hook-up wire supplied)
|
|
CONTROLS
|
Manual air shutter for summer shut-off affords some control of humidifier output. Model 1042 LH includes GENERALAire H-86 wall/duct mount humidistat.
|
GENERALAire H-86 wall/duct mount humidistat.
|
|
CONSTRUCTION, MATERIALS AND STYLING
|
Attractive cabinet made from durable,non-corrosive, high temperature materials for long service life.
|
Attractive cabinet made from durable, non-corrosive, high temperature materials for long service life.
|
|
VERSATILITY
|
Right or left hand bypass installation. May be installed on up-flow, counter-flow or horizontal furnaces or air handlers.
|
Single plenum design fits minimum space situations. Motor-driven fan eliminates bypass pipe. May be installed on up-flow or horizontal furnaces or air handlers.
|
|
SERVICEABILITY
|
Thumbscrews allow easy access to distribution trough, drain pan and evaporative pad for quick, easy cleaning and service.
|
Thumbscrews allow easy access to the distribution trough, drain pan and evaporative pad for quick, easy cleaning and service. Simple, removable back cover allows easy access to electrical components.
|
|
EASY INSTALLATION - GENERALAire humidifers are specially designed for fast, easy installation
|
Most important components are included. Outboard and keyholed screw holes and simple thumbscrew assembly speeds installation. Patented water distribution tray reduces need for critical leveling.
|
Most important components are included. Outboard screw holes and simple thumbscrew assembly speeds installation. Patented water distribution tray reduces need for critical leveling. Guarded fan blade assures safety.
|